Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 40(12): 2094-2101, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31727754

RESUMO

BACKGROUND AND PURPOSE: The recently introduced Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield) is the third generation of Pipeline flow-diverter devices. It has a new stent-surface modification, which reduces thrombogenicity. We aimed to evaluate clinical and radiographic (safety and efficacy) outcomes of the Pipeline Shield. MATERIALS AND METHODS: The 30-day and 1-year mortality and morbidity rates and the 6- and 18-month radiographic aneurysm occlusion outcomes for procedures performed between March 2016 and January 2018 were analyzed. 3D-TOF-MRA was used for follow-up. RESULTS: Forty-four attempted Pipeline Shield procedures were performed for 41 patients with 44 target aneurysms (total of 52 aneurysms treated). A total of 88.5% of devices were inserted in the anterior circulation, and 11.5%, in the posterior circulation; 49/52 (94.2%) aneurysms were saccular; and 1/52 (1.9%) was fusiform. One (1.9%) aneurysm was an iatrogenic pseudoaneurysm, and 1 (1.9%) was a dissecting aneurysm. Seventy-one percent (35/49) of the saccular aneurysms were wide-neck (neck, >4 mm), 34.6% (18/52) were large (≥10 mm), and 3.8% (2/52) were giant (≥25 mm). The mean aneurysm sac maximal diameter was 9.0 mm, and the mean neck width was 5.0 mm. The cumulative mortality and morbidity rates were 2.3% and 6.8% at 1 year, respectively. The adequate occlusion rate was 78.8% at 6 months and 90.3% at 18 months. CONCLUSIONS: In this pragmatic and non-industry-sponsored study, the occlusion rates and safety outcomes were similar to those seen in previously published studies with flow-diverter devices and earlier generation Pipeline Embolization Devices.


Assuntos
Prótese Vascular , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Resultado do Tratamento , Adulto Jovem
6.
Acta Endocrinol (Buchar) ; 13(1): 60-64, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-31149149

RESUMO

PURPOSE: To investigate whether there is a difference between acromegalic and non-acromegalic cases in terms of bowel preparation and colonoscopic intervention. METHODS: Patients with controlled and uncontrolled acromegaly and as a control group (CG) patients without acromegaly between January 2010 and March 2014 were included. Groups were compared regarding adequacy of bowel preparation, cecal insertion time (CIT) and colonoscopy results. RESULTS: Fifty-nine patients with acromegaly (controlled n=30, uncontrolled n=29) and 73 age and gender matched volunteers without acromegaly were evaluated. CIT in cases with controlled, uncontrolled acromegaly cases and in CG was 5.33 [4.00-6.00], 7.00 [4.91-11.31], and 3.10 [2.35-4.65] minutes, respectively (p<0.001). Cases in CG had shorter CIT compared to controlled and uncontrolled acromegaly cases ( p=0.014 and p<0.001, respectively). There was no significant difference regarding CIT between controlled and uncontrolled acromegaly cases (p=0.247). Six (20%) of controlled acromegaly patients, 10 (35%) of uncontrolled acromegaly patients and three (4%) of CG had inadequate bowel cleansing (p<0.001). Although statistically insignificant, cases with inadequate bowel cleansing had tendency towards having prolonged CIT in comparison to cases with adequate bowel cleansing (6.00 [3.87-9.00] and 4.16 [2.95-5.70] minutes, respectively, p=0.07). CONCLUSION: Inadequate bowel cleansing is one of the main problems encountered during colonoscopic investigation/surveillance in acromegalic patients. Therefore, a different protocol for colonoscopy preparation may be needed for these cases.

10.
Br J Radiol ; 83(991): e147-9, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20603400

RESUMO

The radioguided occult lesion localisation (ROLL) technique is used for the excision of non-palpable breast lesions. This technique has not been described previously for the extraction of foreign bodies from the breast parenchyma. We report here a female patient who was admitted to our hospital with a foreign body in her right breast. The ROLL technique was used for the extraction of the foreign body.


Assuntos
Mama , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia , Compostos Radiofarmacêuticos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Adulto , Feminino , Humanos , Mamografia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Agulhas , Cintilografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...